Task preview

НомерprojectCategoryVisibilityИзменен
0001903RasKonWishespublic2020-06-09 11:56
InitiatorADGroup ResponsibleADGroup  
PriorityordinaryInfluencesmallReproducibilityuntested
Condition closedDecisionsolved 
Целевая версия10.35Решена в версии10.35 
Theme0001903: Function for automatic assignment of one welded impost in a structure according to specified criteria.
DescriptionOptions 2" tab of "Options 2" menu "Settings" / "Environment: Global Parameters" added parameters:
"Assign welded impost in the construction automatically - one vertical impost" - when this option is set, the program will select only one vertical impost among all installed welded imposts (according to the settings) in the construction as a welded one, the other welded imposts will become normal (not welded). For the correct operation of the function in "Settings" / "Construction elements" the option "Welded impost" must be set for the imposts and the corresponding accessories must be configured for this impost depending on whether it will be welded or will remain a regular impost. For this purpose, in the "Settings" / "Construction elements" window in the "Material settings editor" window, two options have been added: "Consider welded impost" and "Welded impost".
"Welded impost in the design assigned automatically must be without hinges" - when this option is set, the program will select impost without hinges installed on it, so that impost will not be loaded by the sash.
"Maximum length of automatically assigned welded impost in the design, mm". - sets the maximum length of the automatically selected welded impost.
"Type of impost welding "90 degrees", otherwise "wedge""" - standard before this version of the program there was only one type of welded impost - "wedge", now when this option is set, the welded impost will be like a regular impost cut off at the ends at 90 degrees, but only taking into account its "weld", which is set in the menu "References" / "Manufacturers" in the window "Manufacturer settings" - "Impost weld "90 degrees"".
Also in the print form editor for profile stickers a condition has been added:
"BOOLRPRDetIsImpostWelding" - this condition will be true if the sticker will be printed for welded impost.
TagsThere are no associated tags.
Number of references
Implementation period (days)
Cost
Planned date

Connections

related to 0001922 closedADGroup Corrects errors on the function of automatic assignment of a welded impost in a structure. 
related to 0001923 closedADGroup Added option "Welded impost in the design assigned automatically must be the only one (normal ones are not allowed)" 
related to 0001924 closedADGroup Added option Welded impost in design not to assign to "door", "lamination", "oversized", "non-rectangular", "arched" 

Activity

ADGroup

2020-03-25 11 :09

administrator ~0001955


Community support for the task
This problem is marked solved.
If you think it is not, please reopen it and explain why.
Supporters: No supporters have yet voted in favor of the task.
Neutrality: No users have yet voted neutral for this task.
Opponents: No opponents have yet voted in favor of this task.

Change history

Date of change User Field Modify
2020-03-25 09:37 ADGroup New task
2020-03-25 09:37 ADGroup Condition new => assigned
2020-03-25 09:37 ADGroup Responsible => ADGroup
2020-03-25 11:05 ADGroup Description changed
2020-03-25 11:09 ADGroup Description changed
2020-03-25 11:09 ADGroup Condition assigned => closed
2020-03-25 11:09 ADGroup Decision open => solved
2020-03-25 11:09 ADGroup Resolved in version => 10.35
2020-03-25 11:09 ADGroup Comment added: 0001955
2020-06-09 09:40 ADGroup Link added related to 0001922
2020-06-09 11:55 ADGroup Link added related to 0001923
2020-06-09 11:56 ADGroup Link added related to 0001924