Theme0000869: The article of the glass bags is not displayed on any print form.
DescriptionIt is necessary to separate the name of glass packages (Single Chamber) and their formula (4-10arg-4-10-4i), for the customer the name and for the manufacturer the formula. Since neither the article nor the note can not be displayed on the printed forms, but only the name it is impossible to do. The method proposed by technical support is not exactly what solves this problem.
TagsThere are no associated tags.
Number of references
Implementation period (days)
Cost
Planned date

Activity

ADGroup

2015-04-06 11 :26

administrator ~0000812

The article is not really displayed, because the article will match the insulating glass unit only if the insulating glass unit is configured as "purchased", but if the insulating glass unit is configured as glass+distance+screen+sealant, then the article of each material is different and has nothing to do with the product called insulating glass unit. It may be necessary to solve the issue differently. In your application you did not specify the print forms (tables) on which you would like to see the "article of the double-glazed unit".

mebitar

2015-04-06 14 :44

author ~0000813

Last modified: 2015-04-06 14 :45

It is necessary that there were variables in the printed forms of applications for slopackets №52,53,54,55,56 worked "Name", "Article" or "Note" that it would be possible to separate on the applications Name and Article for "purchased" packages. The essence of the problem is that it is necessary on the commercial proposal visibility "Name (One-chamber-energo)" and on the application for purchased packages "Article(4-16-4i)" or "Note(4-16-4i) "that is a formula. I tried to insert the formula in the note, but it pulls out only the factor of availability of non-standard, and the Article is not displayed.

mebitar

2015-04-07 01 :23

author ~0000814

As a solution, you can add a variable "Formula" type of text note and was selected from the material directory, or change the variable "Note" that would select the note that is recorded in the material directory.

ADGroup

2015-04-07 01 :38

administrator ~0000815

Yes, I thought of that, just not in the material reference, but in the design element settings in the glazing section.

Community support for the task
Only registered users can vote. Register, or login.
Supporters: No supporters have yet voted in favor of the task.
Neutrality: No users have yet voted neutral for this task.
Opponents: No opponents have yet voted in favor of this task.

Change history

Date of change User Field Modify
2015-04-01 23:03 mebitar New task
2015-04-06 11:26 ADGroup Comment added: 0000812
2015-04-06 14:44 mebitar Comment added: 0000813
2015-04-06 14:45 mebitar Comment modified: 0000813
2015-04-07 01:23 mebitar Comment added: 0000814
2015-04-07 01:38 ADGroup Comment added: 0000815